璁婂鍣ㄦ櫤鑳介ⅷ鍐锋帶鍒舵珒 浣犵従鍦ㄧ殑浣嶇疆锛棣栭爜 - 鐢e搧灞曠ず - 璁婂鍣ㄦ櫤鑳介ⅷ鍐锋帶鍒舵珒

ZY-W-100婧繒搴︽帶鍒跺櫒

鍦栭泦绨′粙

ZY-W-100婧繒搴︽帶鍒跺櫒

婧繒搴︽帶鍒跺櫒ZY -W - 100
The temperature and humidity controller ZY-W-100
涓.涓昏鍔熻兘The primary functions
甯朵竴璺韩搴﹀偝鎰熷櫒鍜屼竴璺嚌闇插偝鎰熷櫒锛 闅忔檪鐩f脯鐠
澧冪殑婧繒搴﹁畩鍖栨儏娉侊紝 鐣舵繒搴﹂仈鍒颁竴瀹氭垨婧害璁婂寲鍔囧
锛 鏈夌敚鐢熷嚌闇茬殑鍙兘鏅傦紝 鎺у埗鍣ㄩ﹨鍕曞姞鐔卞櫒锛 鐮村鐢g敓
鍑濋湶鐨勬浠躲傜暥鐢g敓鍑濋湶鐨勬浠舵秷澶卞緦锛 鍔犵啽鍣ㄨ嚜鍕曟柗
闁嬶紝 鎺у埗鍣ㄦ仮瑜囧埌鐩f脯鐙鎬併
The first temperature transducer and the dew sensor, always check to see the environmental changes in temperature or humidity, when the humidity got higher and higher,or the temperature is greatly changed and can run drew, the heater of controller to cause interference. when unfavourable factors disappeared, the heater automatic breaking-off and the state of being restored.
浜.鎶琛撴寚鏍嘥he technique index

1銆佷緵闆婚浕婧愶細A C 2 3 0 V卤1 0 %锛6 0 H z锛
Power supplies: A C 2 3 0 V卤1 0 %锛 6 0 H z锛
2銆佸伐浣滅挵澧冿細婧害- 2 0鈩 锝7 0鈩冩繒搴︹墹9 5 % R H
Environment: temperature: - 2 0鈩 锝7 0鈩, humidity: 鈮9 5 % R H
3銆佹韩鍗鎺у埗绡勫湇锛5鈩冿綖2 0鈩
The range of scream temperature: 5鈩冿綖2 0鈩
4銆佹韩搴︽帶鍒剁簿搴︼細卤1鈩
The control precision: 卤1鈩
5銆佹繒搴︽帶鍒剁瘎鍦嶏細1 0 % R H锝9 5 % R H 鍑濋湶鍟熸帶锛氣墹9 5 % R H
The range of humidity: 1 0 % R H锝9 5 % R H drew arrested: 鈮9 5 % R H
6銆佽几鍑烘帴榛烇細闃绘 C 2 2 0 V锛3 A
Contact output: Resistive A C 2 2 0 V锛3 A
7銆佸姛鑰楋細鈮2 W
Consumption: 鈮2 W
8銆佸彲闈犲畨鍏ㄦэ細绗﹀悎I E C 8 3 4 - 1瑕佹眰
Safety testing: Conform to I E C 8 3 4 - 1
9銆佸褰㈠昂瀵革細4 8脳4 8脳9 0
Overall dimensions:4 8脳4 8脳9 0
1 0銆侀枊瀛斿昂瀵革細4 5脳4 5
Perforation size: 4 5脳4 5
涓.瀹夎浣跨敤Installation
鎺ョ窔鍦杦iring diagram
闈㈤梿寮忓畨瑁 micropanel Installation 搴曞骇寮忓畨瑁漟oundation installation






鍥.鍌虫劅鍣ㄧ殑瀹夎The Installation of transducer
1銆佸嚌闇插偝鎰熷櫒 The dew transducer
锛1锛夊皢鍌虫劅鍣ㄥ叐鍓囷紝鐢4 M鍥哄畾鍦ㄨ娓櫒浠剁殑娈奸珨涓娿
The side of transducer was fixed in the shell with 4M
锛2锛夊皢鍌虫劅鍣ㄦ彃鍏ュ皫杌屾Ы瑁°
The transducer put in single channel
锛3锛夋韩搴﹀偝鎰熷櫒瀹夎鏂瑰紡鑸囧嚌闇插偝鎰熷櫒鐩稿悓
The way of temperature transducer installation is same to the dew sensor.
锛4锛夋敞锛氬唴缃偝鎰熷櫒鐒¢渶鐢ㄦ埗瀹夎銆
Note: The built-in transducer without user installation.
浜斻佷娇鐢ㄦ柟娉昦pplication
1銆佹寜鍦栨帴绶氾紝閫氶浕寰岋紝闁嬪暉鎸囩ず鐕堜寒锛屾豢瓒冲姞鐔辨浠讹紝
琛ㄧず鍔犵啽鍣ㄥ伐浣溿
Follow the wiring diagram, the power has been turn on, the indicator lights up, meet the conditions for heating, and express the heater is normal work.
2銆佸闇瑭﹂鍑濋湶鎰熸繒寰岀殑鍔犵啽宸ヤ綔鎯呮硜锛屽湪婧害澶т簬
20搴︾挵澧冧腑锛屽彲灏嗗嚌闇插偝鎰熷櫒鏀惧叆鍐扮绱5鍒嗛悩寰屽彇鍑猴紝
渚嗘ā浼煎嚌闇叉浠讹紝鎴栫敤灏嶅嚌闇插偝鎰熷櫒鍝堟埃鐨勬柟娉曢茶锛
瑙瀵熷嚌闇叉浠朵笅鐨勫伐浣滄儏娉
If need to test the heating work when the drew feeling the dry ,in the environment if the environment temperature is high than 20鈩,you can put the dew sensor in the refrigerator about five minutes to simulate drew conditions,or blew against the dew sensor, to observations work in the dew conditions.


瑭崇窗瑾槑
 

婧繒搴︽帶鍒跺櫒ZY - W - 1 0 0

The temperature and humidity controller ZY-W-100

.涓昏鍔熻兘The primary functions

甯朵竴璺韩搴﹀偝鎰熷櫒鍜屼竴璺嚌闇插偝鎰熷櫒锛 闅忔檪鐩f脯鐠

澧冪殑婧繒搴﹁畩鍖栨儏娉侊紝 鐣舵繒搴﹂仈鍒颁竴瀹氭垨婧害璁婂寲鍔囧

锛 鏈夌敚鐢熷嚌闇茬殑鍙兘鏅傦紝 鎺у埗鍣ㄩ﹨鍕曞姞鐔卞櫒锛 鐮村鐢g敓

鍑濋湶鐨勬浠躲傜暥鐢g敓鍑濋湶鐨勬浠舵秷澶卞緦锛 鍔犵啽鍣ㄨ嚜鍕曟柗

闁嬶紝 鎺у埗鍣ㄦ仮瑜囧埌鐩f脯鐙鎬併

The first temperature transducer and the dew sensor, always check to see the environmental changes in temperature or humidity, when the humidity got higher and higher,or the temperature is greatly changed and can run drew, the heater of controller  to cause interference. when unfavourable factors disappeared, the heater automatic breaking-off and the state of being restored.

.鎶琛撴寚鏍The technique index

 

1銆佷緵闆婚浕婧愶細A C 2 3 0 V1 0 %6 0 H z

   Power supplies: A C 2 3 0 V1 0 % 6 0 H z

2銆佸伐浣滅挵澧冿細婧害- 2 0 7 0婵曞害鈮9 5 % R H

Environment: temperature: - 2 0 7 0, humidity: 9 5 % R H

3銆佹韩鍗鎺у埗绡勫湇锛5鈩冿綖2 0

   The range of scream temperature: 5锝2 0

4銆佹韩搴︽帶鍒剁簿搴︼細卤1

   The control precision: 1

5銆佹繒搴︽帶鍒剁瘎鍦嶏細1 0 % R H9 5 % R H 鍑濋湶鍟熸帶锛氣墹9 5 % R H

   The range of humidity: 1 0 % R H9 5 % R H drew arrested: 9 5 % R H

6銆佽几鍑烘帴榛烇細闃绘A C 2 2 0 V3 A

   Contact output: Resistive A C 2 2 0 V3 A

7銆佸姛鑰楋細鈮2 W

   Consumption: 2 W

8銆佸彲闈犲畨鍏ㄦэ細绗﹀悎I E C 8 3 4 - 1瑕佹眰

   Safety testing: Conform to I E C 8 3 4 - 1

9銆佸褰㈠昂瀵革細4 84 89 0

   Overall dimensions:4 84 89 0

1 0銆侀枊瀛斿昂瀵革細4 54 5

     Perforation size: 4 54 5

.瀹夎浣跨敤Installation

鎺ョ窔鍦wiring diagram

闈㈤梿寮忓畨瑁   micropanel Installation        搴曞骇寮忓畨瑁foundation installation

 

 

 

 

 

 

.鍌虫劅鍣ㄧ殑瀹夎The Installation of transducer

1銆佸嚌闇插偝鎰熷櫒 The dew transducer

1锛夊皢鍌虫劅鍣ㄥ叐鍓囷紝鐢4 M鍥哄畾鍦ㄨ娓櫒浠剁殑娈奸珨涓娿

     The side of transducer was fixed in the shell with 4M

2锛夊皢鍌虫劅鍣ㄦ彃鍏ュ皫杌屾Ы瑁°

     The transducer put in single channel

3锛夋韩搴﹀偝鎰熷櫒瀹夎鏂瑰紡鑸囧嚌闇插偝鎰熷櫒鐩稿悓

     The way of temperature transducer installation is same to the dew sensor.

 4锛夋敞锛氬唴缃偝鎰熷櫒鐒¢渶鐢ㄦ埗瀹夎銆

     Note: The built-in transducer without user installation.

浜斻佷娇鐢ㄦ柟娉application

1銆佹寜鍦栨帴绶氾紝閫氶浕寰岋紝闁嬪暉鎸囩ず鐕堜寒锛屾豢瓒冲姞鐔辨浠讹紝

琛ㄧず鍔犵啽鍣ㄥ伐浣溿

Follow the wiring diagram, the power has been turn on, the indicator lights up, meet the conditions for heating, and express the heater is normal work.

2銆佸闇瑭﹂鍑濋湶鎰熸繒寰岀殑鍔犵啽宸ヤ綔鎯呮硜锛屽湪婧害澶т簬

20搴︾挵澧冧腑锛屽彲灏嗗嚌闇插偝鎰熷櫒鏀惧叆鍐扮绱5鍒嗛悩寰屽彇鍑猴紝

渚嗘ā浼煎嚌闇叉浠讹紝鎴栫敤灏嶅嚌闇插偝鎰熷櫒鍝堟埃鐨勬柟娉曢茶锛

瑙瀵熷嚌闇叉浠朵笅鐨勫伐浣滄儏娉

If need to test the heating work when the drew feeling the dry ,in the environment if the environment temperature is high than 20,you can put the dew sensor in the refrigerator about five minutes to simulate drew conditions,or blew against the dew sensor, to observations work in the dew conditions.